Datalogic POWERSCAN 7000 2D Imager Product Reference Manual page 72

2d imager
Hide thumbs Also See for POWERSCAN 7000 2D Imager:
Table of Contents

Advertisement

Symbologies
When Check Character is set to Validate, but Don't Transmit, the unit
will only read Codabar bar codes printed with a check character, but will
not transmit the check character with the scanned data.
* No Check Character
Validate Modulo 16
and Transmit
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatena-
tion, the imager looks for a Codabar symbol having a "D" start character,
adjacent to a symbol having a "D" stop character. In this case the two
messages are concatenated into one with the "D" characters omitted.
Default = On.
Character
Codabar
Select Require to prevent the imager from decoding a single "D" Coda-
bar symbol without its companion. This selection has no effect on Cod-
abar symbols without Stop/Start D characters.
On
Require
6-4
Start
Stop
Start
Stop
A12D
D34A
PowerScan
Validate Modulo 16, but
Don't Transmit
* Off
®
7000 2D