3.2.1 Housing Removal
Since the EPSON Stylus Photo has no lower housing as previous EPSON printers, the printer mechanism
can be taken out by only removing the upper housing.
1.
Open the printer cover and set the PG adjust lever on the right-hand side to (+) position.
2.
Remove 4 screws (No.2) and remove the upper housing.
Pull the front end of the upper housing while lifting up the upper housing to remove it.
Be careful not to pinch the cables with the posts of the upper housing when reinstalling it. (Especially
with the cables from the motors and doing so causes fatal damage to the mechanism and the electric
circuitry.)
Rev. A
WORK POINT
CAUTION
Figure 3-2. Housing Removal
Chapter 3 Disassembly and Assembly
3-5