Configure The Settings Relating To Rs485 [Rs485 Setup] - Panasonic WJ-HD616/1000 Installation Manual

Digital disk recorder
Hide thumbs Also See for WJ-HD616/1000:
Table of Contents

Advertisement

Configure the settings relating to RS485 [RS485 setup]
Select the [RS485 setup] tab on the "Communication" page. (+ Page 60)
The settings for RS485 can be configured on this tab.
[Protocol]
Select the protocol used for RS485 communication.
Panasonic/Pelco-D
Default: Panasonic
[Baud rate]
Select a communication speed for data transmission with a
connected device from the following:
2 400/4 800/9 600/19 200/38 400 (bps)
Default: 19 200
[Control camera ch]
Allocate the RS485 port 1 and port 2 to camera channels.
When the [Setup] button is selected, the following page will
be displayed.
• [TERM]
Select a port to be controlled from the following for each
camera channel.
PORT1: Controls from the RS485 port 1.
PORT2: Controls from the RS485 port 2.
• [Back] button
Closes the setup page and returns to the [RS485 setup]
tab.
94
[Data bit]
The data length for communication will be displayed.
7/8 (bit)
Default: 8
[Parity]
Methods of error check for a transmission at communication
will be displayed.
NONE: No parity check
EVEN: Even parity
ODD: Odd parity
Default: NONE
[Stop bit]
Stop bit types will be displayed.
1/2 (bit)
Default: 1

Hide quick links: