Cascading connection of multiple recorders

Up to 5 recorders can be connected in cascading connection.
When connecting recorders in cascading connection, images displayed on Monitor 2 connected to the second and subsequent
recorders can be switched and displayed on Monitor 2 connected to the first recorder.
Use the cascade input connector, cascade output connector (monitor output connector 2 is provided as the dual purpose con-
nector) and DATA port.
Cables are to be connected differently between when using HDMI cables and when using BNC cables.
Important:
• When multiple recorders are connecting in cascading connection, select "On" for the "Cascade" setting on the [Cascade] tab
under the "Display" page of the setup menu. (+ Page 91)
• When connecting in cascading connection, all cables used to connect to the monitor connector shall be HDMI cables only or
BNC cables only. Do not use them together.
• Do not assign the same unit address to two or more different PS·Data compatible devices.
• Set the unit address (system) of the recorders to "1" to "5".
• In cascading connection, the time of recorders is automatically adjusted to that of the recorder whose unit address (system)
is set to "1".
• When connecting in cascading connection, all recorders shall be WJ-HD616K.
Cascading connection using BNC cables
Monitor 2
16
IN
OUT
16
BNC cable
(locally procured)
BNC cable
(locally procured)
16
IN
Monitor 1
OUT
16
BNC cable
(locally procured)
16
IN
Monitor 1
OUT
16
Monitor 1
* When also connecting audio cables in cascading connection
Mode switch
ON
1 2 3 4 5
EXT STORAGE
MODE
DATA
RS485(CAMERA) 10/100BASE-T
3
2
1
1 2 3 4 5 6 7 8
2
1
1
3
1
MONITOR
OUT
ALARM
2
2
1
2
1
4
2
ALARM/CONTROL
OUT-CASCADE-IN
CASCADE IN
OUT MONITOR OUT(HD)
AUDIO IN
15
14
13
12
11
10
9
8
7
6
5
4
3
7
15
14
13
12
11
10
9
8
7
6
5
4
3
VIDEO
RS485
cable
(WV-CA
48/50)
EXT STORAGE
MODE
DATA
RS485(CAMERA) 10/100BASE-T
3
2
1
1 2 3 4 5 6 7 8
2
1
1
3
1
MONITOR
OUT
ALARM
2
2
1
2
1
4
2
ALARM/CONTROL
OUT-CASCADE-IN
CASCADE IN
OUT MONITOR OUT(HD)
AUDIO IN
15
14
13
12
11
10
9
8
7
6
5
4
3
7
15
14
13
12
11
10
9
8
7
6
5
4
3
VIDEO
RS485
cable
(WV-CA
48/50)
EXT STORAGE
MODE
DATA
RS485(CAMERA) 10/100BASE-T
3
2
1
1 2 3 4 5 6 7 8
2
1
1
3
1
MONITOR
OUT
ALARM
2
2
1
2
1
4
2
ALARM/CONTROL
OUT-CASCADE-IN
CASCADE IN
OUT MONITOR OUT(HD)
AUDIO IN
15
14
13
12
11
10
9
8
7
6
5
4
3
7
15
14
13
12
11
10
9
8
7
6
5
4
3
VIDEO
Powered
speaker
(No.7: OFF)
(No.8: ON)
Audio cable
6
7 8
(locally procured)
The "Unit address" setting on the
[PS·Data setup] tab under
"Communication" of the setup
menu
IN
CASCADE
OUT
AUDIO
OUT
2
1
POWER
First recorder
ON
1
OFF
System:
OUT
2
Controller: 1
AC IN
SIGNAL
GND
Mode switch
(No.7: OFF)
ON
(No.8: OFF)
1 2 3 4 5
6
7 8
IN
CASCADE
Second recorder
OUT
System:
AUDIO
OUT
2
1
POWER
Controller: 2
ON
1
OFF
OUT
2
AC IN
SIGNAL
GND
Mode switch
ON
(No.7: OFF)
(No.8: ON)
1 2 3 4 5
6
7 8
Third recorder
IN
CASCADE
System:
OUT
AUDIO
Controller: 3
OUT
2
1
POWER
ON
1
OFF
OUT
2
AC IN
SIGNAL
GND
Audio cable
(locally procured)
1
2
3
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wj-hd716/1000Wj-hd616kWj-hd716k

Table of Contents