Power Control; Server Management Commands - HP rp7420 Service Manual

Hp 9000 rp7420 server - user service guide, fifth edition
Hide thumbs Also See for rp7420:
Table of Contents

Advertisement

NOTE:
Fans driven to a high RPM in dense air cannot maintain expected RPM and will be
considered bad by the MP leading to a "False Fan Failure" condition.

Power Control

If active, the manageability firmware is responsible for monitoring the power switch on the front
panel. Setting this switch to the ON position is a signal to the MP to turn on 48 V DC power to
the server. The PE command can also be used to send this signal. This signal does not always
generate a transition to the powered state. The following conditions prevent the manageability
firmware from applying 48 V DC power to the server:
Insufficient number of active bulk power supplies
Insufficient number of I/O fans
Insufficient number of main fans
Ambient temperature is in an OVERTEMP HIGH condition
Unless one of the following conditions occurs, 48 V DC power to the server is maintained:
A main fan failure causes there to be an insufficient number of main fans.
A I/O fan failure causes there to be an insufficient number of I/O fans.
Ambient temperature reaches an OVERTEMP HIGH condition.
The front panel power switch is turned OFF.
The PE command is issued to the manageability firmware to turn off power to the server
cabinet.

Server Management Commands

For a list of the server management commands, go to the iLO 2 Operations Guide at
docs.hp.com.
http://
Server Management Commands
81