Figure 4-5 Wall Receptacle Pinouts
WARNING!
insulated probes.
5.
Verify that the voltage between receptacle pins x and y is between 200 and 240 V AC.
6.
Set the site power circuit breaker to Off.
7.
Ensure that power is removed from the server.
8.
Route and connect the server power connector to the site power receptacle.
For locking type receptacles, line up the key on the plug with the groove in the receptacle.
Push the plug into the receptacle and rotate to lock the connector in place.
WARNING!
verifying that the cabinet has been wired into the site AC power supply correctly. Failure
to do so might result in injury to personnel or damage to equipment when AC power is
applied to the cabinet.
9.
Set the site power circuit breaker to On.
10. Set the server power to On.
11. Check that the indicator light on each power supply is on.

MP Core I/O Connections

Each HP 9000 rp7420 server can have up to two MP core I/O board sets installed. Which allows
two partitions to operate, or MP core I/O redundancy in a single partition configuration. Each
MP core I/O board set consists of two boards: the MP/SCSI board and the LAN/SCSI board. The
MP/SCSI board is oriented vertically and accessed from the back of the server. The LAN/SCSI is
accessed from the PCI/PCI-X expansion card bay. Only the primary MP core I/O board set
(MP/SCSI slot 1 and LAN/SCSI slot 8, chassis 1) is required for a single partition implementation.
The secondary MP/SCSI board is not necessary for full operation. However, without the secondary
MP/SCSI board, only two internal disks can be accessed.

MP/SCSI Connections

The MP/SCSI board is required to update firmware, access the console, turn partition power on
or off, access all but two of the internal peripherals, and use other features of the server.
Connections to the MP/SCSI board include the following:
There is a risk of shock hazard while testing primary power. Use properly
Do not set site AC circuit breakers serving the processor cabinets to On before
MP Core I/O Connections
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9000 rp7420

Table of Contents