High Limit Switch Keeps Tripping

Possible Causes:
1.
The convection blower is overheating and tripping the internal
temperature shutoff.
2.
The stove is being left on the highest setting for extended periods of
time.
3.
Fuel other than wood pellets or whole shelled corn is being burned in
the stove.
4.
Power surge or brown out situation.
5.
High limit switch is malfunctioning.
Heat Level
Heat Level
SMOKE SMELL OR SOOT BUILD-UP
Because it is a solid-fuel burning device, your SP 6000 Multi-Fuel may emit a faint odor. If this smell is excessive, or
noticeably increases over time, or if you notice an unusual soot build-up on walls or furniture, check your exhaust system
carefully for leaks. All joints should be properly sealed. Also clean your stove, following instructions given under
"MAINTENANCE". If problem persists, contact your dealer.
TROUBLESHOOTING GUIDE

Digital Circuit Board Timing Rates

On Time
1
1.66 seconds
2
1.66 seconds
3
1.66 seconds
4
1.66 seconds
5
1.66 seconds

Stir Motor Timing Rates

On Time
1
10 seconds
2
10 seconds
3
10 seconds
4
10 seconds
5
10 seconds
Possible Remedies:
Clean any dust off of the windings and fan blades. If oiling the blower
does not help, the blower may be bad.
The highest heat level setting is designed for use over short periods of
time. Burning the stove on the highest setting for longer than 20 minutes
is not recommended.
This stove is designed and tested to use whole shelled corn or pelletized
wood pellets. These are the only authorized and approved fuels available.
No other types of fuel have been approved. Use of alternative fuels will
void the warranty and could pose a significant fire hazard.
A power surge, spike, or voltage drop could cause the high limit switch to
trip. Check to see if a surge protector is being used on the stove. If not,
recommend one to the consumer.
If the other items check out ok, replace the high limit switch.
Off Time
8.34
5.04
3.44
2.44
1.74
Off Time
10 seconds
6 seconds
3.5 seconds
1.5 seconds
0 seconds
22
.
Total Cycle
10 seconds
6.7 seconds
5.1 seconds
4.1 seconds
3.4 seconds
.
Total Cycle
20 seconds
16 seconds
13.5 seconds
11.5 seconds
10 seconds