Control Panel Reset

It may become necessary to reset the control panel to the original factory specifications and settings. This could be due
to erratic operation from the control panel, power fluctuations, or other reasons. It is easy to accomplish and will often
correct any frustrating issues that you may be having.
In order to reset the control panel, follow the directions below:
 Turn the stove OFF (No lights on control board and allow the stove to cool until all fans are
turned off) Unplug the stove and wait at least one full minute, then plug the unit back in.
 Simultaneously press (briefly):
[AUGER FEED] + [HEAT LEVEL HIGH] + [FAN SPEED HIGH] + [FAN SPEED LOW]
 ** ALL RED/GREEN/YELLOW lights should blink ONCE
IMPORTANT: ALL lights should blink ONCE – if not, repeat the procedure.
Note: The SP6000 series 4100 board has 4 programs. These programs are currently used to adjust the combustion fan
voltage to compensate for local electrical grid conditions. If the control board lights blink more than once (two, three, or
four times), the board has been put into another program. If this occurs, repeat this RESET procedure again until the
lights blink only once.
OPERATION

SET THE CONTROL BOARD:

For further assistance, please call Breckwell Technical Support (toll free)
866-606-8444 ext. 111
WHEN IN DOUBT, RESET THE BOARD