INSTALLATION

Combustion Air Supply

A 2" inside diameter metallic pipe, either flexible or rigid, may be
attached to the inlet at the stove's rear. A rodent guard (minimum
¼" wire mesh)/wind hood must be used at the terminus. All
connections must be secured and airtight by either using the
appropriately sized hose clamp and/or UL-181-AP foil tape.
NOTE: A C
OMBUSTION AIR SUPPLY IS REQUIRED FOR ALL MOBILE HOME
AND ALSO IN CONVENTIONAL HOME INSTALLATIONS IF THE
,
INSTALLATIONS
,
,
UNIT IS BEING INSTALLED IN A BASEMENT
SMALL ROOM
OR EXTREMELY
.
WELL INSULATED OR AIRTIGHT HOMES
F
: For a mobile home
OR MOBILE HOME INSTALLATIONS ONLY
installation the stove must be connected to an outside source of
combustion air per federal regulations. 2" inside diameter pipe may
be used for the first 5 feet of combustion air supply run. From 5 to
10 feet use 2 ¾" inside diameter pipe.
N
10
EVL.
O COMBUSTION AIR SUPPLY MAY EXCEED
FEET OF
EVL (Equivalent Vent Length) for combustion air supply is calculated
the same as for the venting or exhaust pipe.
S
O
C
A
OURCES OF
UTSIDE
OMBUSTION
IR
In fireplaces, outside air can be piped to the stove from the chimney
top, fireplace ash clean out door, or a hole drilled through the back of
the fireplace. The run of pipe for the combustion air supply should be
as short as possible for the best performance.
For freestanding installations, this could be a hole in the floor
near the stove rear terminating in a ventilated crawl space,
or a hole in the wall behind the stove.
In tightly insulated homes, a closeable outside air register can be
used.
W
O
A
I
N
U
HEN
UTSIDE
IR
S
OT
SED
If outside air is not used, it is important that the combustion air inlet is
not restricted or blocked in any way.

Electrical Installation

This stove is provided with a 6-foot grounded electrical cord extending from the rear of the stove. We recommend
connecting to a good,
that is plugged into a standard three-prong, 120V, 60 Hz electrical
HIGH QUALITY SURGE PROTECTOR
outlet. It is highly recommended that you get a surge protector rated as close to 130 Volts and 10 AMPS as possible. The
closer your surge protector is to these ratings, the greater the protection for your stove.
Voltage variations or incorrect polarity can lead to serious performance problems, especially related to the control board.
The Breckwell electrical system is designed for 120V AC with no more than 5% variation. The polarity of the outlet should
also be checked during installation. Most hardware stores carry an inexpensive polarity checker. Breckwell cannot accept
responsibility for poor performance or damage due to inadequate voltage or incorrect polarity. If connected to an older,
two-prong outlet, a separate ground wire must be run to a proper ground (contact a qualified electrician). Always route
the electrical cord so that it will not come in contact with any hot part of the stove.