IBM NetVista X40 User Manual page 101

Quick reference for netvista 2179 and 6643 systems (dutch)
Hide thumbs Also See for NetVista X40:
Table of Contents

Advertisement

Code
Function
Microprocessor
175
System thermal
180
Status display
201
System memory
Result
Text message
Failed
VRM corresponding to microprocessor in socket
xyzis defective
(where xyz identifies the microprocessor whose
VRM is causing the error message)
VRM corresponding to microprocessor in socket id
xyz is not installed
(where xyzidentifies the microprocessor whose
VRM is causing the error message)
Failed
Fan # n
(where n is the number of the failing fan)
Temperature sensed on processor board is out of
range
Failed
Any failure message
Failed
DIMMs in location DIMM n
(where nis the number of the socket that contains
the failing DIMM)
Test setup error: Corrupt BIOS in ROM
Test setup error: Corrupt DMI BIOS, information
in BIOS is not as expected
Action
Replace the VRM.
If the problem remains,
call for service.
Install a VRM.
If the problem persists,
call for service.
Replace the indicated
fan.
Call for service.
Call for service.
1. Reseat the failing
DIMM.
2. If the problem
remains, replace the
DIMM.
If the problem
persists, call for
service.
If your system does not
have the latest level
BIOS installed, update
the BIOS to the latest
level.
If the problem persists,
call for service.
Chapter 6. Solving problems
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellistation e pro 6836Intellistation e pro 6846

Table of Contents