IBM NetVista X40 User Manual page 100

Quick reference for netvista 2179 and 6643 systems (dutch)
Hide thumbs Also See for NetVista X40:
Table of Contents

Advertisement

Code
Function
089
Microprocessor
®
®
84
IBM
IntelliStation
E Pro: User's Guide IntelliStation E Pro Types 6836, 6846
Result
Text message
Failed
Invalid microprocessor in slot xyz or BIOS setup
problem
(where xyzidentifies the microprocessor that is
causing the error message)
Processor in socket id xyz is installed but not
functioning
(where xyz identifies the microprocessor that is
causing the error message)
Microprocessor in socket id xyz
(where xyz identifies the microprocessor that is
causing the error message)
Processor in socket id xyz is defective
(where xyz identifies the microprocessor that is
causing the error message)
Test setup error: Application microprocessor not
installed or BIOS setup problem
Action
1. Check the system
error log for the
related error
messages.
2. If your system does
not have the latest
level BIOS installed,
update the BIOS.
3. If the problem
remains, replace the
xyz microprocessor
and run the test
again.
If the problem persists,
call for service.
1. Reseat the
microprocessor.
2. If the problem
remains, replace the
microprocessor.
If the problem persists,
call for service.
Replace the
microprocessor.
If the problem persists,
call for service.
1. Verify that the
Application
microprocessor is
installed and seated
correctly.
2. If your system does
not have the latest
level BIOS installed,
update the BIOS.
3. If the problem
remains, replace the
Application
microprocessor and
run the test again.
If the problem persists,
call for service.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellistation e pro 6836Intellistation e pro 6846

Table of Contents