Getting the System Log via the Web Interface
Before starting the web interface, refer to "Opening the Web Page" in "3-1-1 Web Version-upgrade", or
refer to the operating instructions supplied with the unit.
Open the web page and then select "Download" in the left column. Then, click "Download" to the right of
"Save System Log". Download of the system log starts.
Getting the System Log via the Serial Port
Use the MAINTENANCE connector (D-sub 9-pin) on the front panel of the Communication System. (The
AUX CONTROL connector on the rear panel of the Communication System cannot be used for taking a
system log.)
For details on the communication confi guration settings for the software terminal (Hyper Terminal, for
example) on a PC which is connected to the MAINTENANCE connector on the Communication System
by a serial cable (cross), refer to "1-1-9".
During operation, the system log is displayed on the software terminal connected through the serial cable.
VISCA OUT
TERMINAL
/
PCS-XG80
n
When obtaining the system log using the terminal software and a serial cable, the entire system log may
not be collected.
PCS-XG80
Transfer rate: 115200 bps
Data length: 8 bits
STOP bit:
1 bit
Parity bit:
None
(RS-232 cross cable)
Terminal software
Personal computer