Troubleshooting By Error Log; Error Log Display Format - Panasonic KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports Installation Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports:
Table of Contents

Advertisement

4.1.5

Troubleshooting by Error Log

When a major system error occurs in the Hybrid IP-PBX, the ALARM indicator on the front of the Basic Shelf
turns on red, and the system logs the error information.

Error Log Display Format

Below is the display format of the error log. For information about how to view the error log using the KX-
TDA600 Maintenance Console, refer to "2.5.8 Utility—Error Log" in the PC Programming Manual.
Example: KX-TDA600 Maintenance Console
Example: Station Message Detail Recording (SMDR)
04/01/01 10:37AM MJ ALM #000 10000 MPR WDT overflow
04/01/01 11:07AM MN ALM #010 10000 AC power down
04/01/01 03:55PM MN ALM #301 10501 Digital trunk RAI reception
1
2
Description
1
Date
2
Time
3
Level
4
Error Code
3
1
2
3
4
5
Item
The date of the error detection.
The time of the error detection.
Minor (MN ALM)
Displays minor errors, which affect only a certain part of system
operation.
Major (MJ ALM)
Displays major errors, which affect operation of the whole
system, or result in system failure.
The 3-digit error code assigned by the Hybrid IP-PBX.
7
4
5
6
Description
4.1 Troubleshooting
6
Installation Manual
225