Compaq BL20p - HP ProLiant - 512 MB RAM Setup And Installation Manual page 80

Server blade
Table of Contents

Advertisement

Troubleshooting
Table D-4: Is the Server Blade Internal Health LED Solid Green?
Answer
No, it is flashing
green.
D-8
Possible Reasons
The server blade is still in POST. If
the flashing continues after
1 minute, the following conditions
may apply:
Nonvolatile RAM (NVRAM)
may be corrupted.
The system ROM may be
corrupted.
Both the system ROM and
redundant ROM may be
corrupted.
Compaq ProLiant BL20p Server Blade Setup and Installation Guide
continued
Possible Solutions
Wait for the server blade to complete
POST.
Clear the system configuration. Refer to
the "Clearing the System Configuration"
section in this appendix.
Switch to the redundant ROM. Refer to
the "Accessing the Redundant ROM"
section in this appendix.
If the health LED is still not solid green,
do one of the following:
Use the optional diagnostic station
to power the server blade and use
the iLO remote console to continue
the diagnosis.
Use the iLO system status page to
help determine the problem.
Contact a Compaq authorized
service provider for replacement
parts and service.
continued

Advertisement