Server Error Messages
Table C-1: POST Error Messages
Error Code
Critical Failure Detected - System
Shutting Down in
Processor in incorrect socket. -
System Halted!
REDUNDANT ROM ERROR:
Backup ROM invalid. - Run
ROMPAQ to correct error condition
REDUNDANT ROM ERROR:
Bootblock invalid. - Contact
COMPAQ Representative
805-Unsupported Processor
Detected
System will ONLY boot ROMPAQ
Utility.
C-2
Audible
Probable Source
Beeps
of Problem
None
Blower assembly has failed.
None
Processor is installed in
socket 2 only.
None
System ROM and
redundant ROM are both
corrupt.
None
ROM bootblock is corrupt.
None
One or both processors are
unsupported.
Compaq ProLiant BL20p Server Blade Setup and Installation Guide
Action
Replace blower
assembly.
Install processor
in socket 1.
Run ROMPaq
Utility.
Contact
Compaq
authorized
service provider.
Install supported
processors.