Specifications Server Specifications - HP ProLiant DL585 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL585:
Table of Contents

Advertisement

Specifications
Server specifications
Table 35
Server specifications
Feature
Dimensions
Height
Depth
Width
Weight
High-line voltage requirements
Rated input voltage
Rated input frequency
Rated input current
Low-line voltage requirements
Rated input voltage
Rate input frequency
Rated input current
Power supply output power
Rated steady-state power
Maximum peak power
Temperature range
Operating
Non-operating
Relative humidity (non-condensing)
Operating
Non-operating
Maximum wet bulb temperature
Heat dissipation
All manuals and user guides at all-guides.com
Units
17.5 cm (6.88 in)
69.2 cm (27.25 in)
46.3 cm (19.0 in)
30.8 kg, minimum (68 lb, minimum)
44.5 kg, maximum (98 lb, maximum)
180 V to 264 V
47 Hz to 63 Hz
6 A
90 V to 132 V
47 Hz to 63 Hz
12 A
800 W
800 W
10° to 35°C (50° to 95°F)
-30° to 60°C (-20° to 140°F)
20% to 80%
5% to 90%
38.7°C (101.7°F)
3900 BTU/hr