To remove the component:
Power down the server if performing a non-hot-plug installation or maintenance procedure
1.
down the
Extend the server from the rack (on page 23).
2.
Use the T-15 Torx screwdriver attached to the rear of the server to loosen the security screw on the
3.
hood latch.
Lift up on the hood latch handle and remove the access panel.
4.
Install the access panel
Place the access panel on top of the server with the hood latch open. Allow the panel to extend past
1.
the rear of the server approximately 1.25 cm (0.5 in).
Push down on the hood latch. The access panel slides to a closed position.
2.
Use the T-15 Torx screwdriver attached to the rear of the server to tighten the security screw on the
3.
hood latch.
Remove the air baffle
IMPORTANT:
baffle.
Power down the server (on page 23).
1.
Extend or remove the server from the rack
2.
Remove the access panel (on page 24).
3.
CAUTION:
module to be lost.
Disconnect the cable, and then remove the BBWC battery pack.
4.
server" on page 23).
To maintain proper airflow and prevent thermal damage, always install the air
Disconnecting the battery module cable will cause any unsaved data in the cache
("Extend the server from the
("Power
rack" on page 23).
Operations 25