Installing Dimms; Hot-Plug Sas Hard Drive Options - HP DL385 - ProLiant - G5 User Manual

Hp proliant dl385 generation 2 server user guide
Hide thumbs Also See for DL385 - ProLiant - G5:
Table of Contents

Advertisement

DIMM population order
Configuration
Single processor
Dual processor

Installing DIMMs

Power down the server (on page 23).
1.
Extend the server from the rack (on page 23).
2.
Remove the access panel (on page 24).
3.
Remove the air baffle (on page 25).
4.
Open the DIMM slot latches.
5.
IMPORTANT:
Install the DIMM.
6.
Install the air baffle (on page 26,
7.
Install the access panel (on page 25).
8.
Install the server into the rack.
9.
Power up the server (on page 23).
10.
For more information about LEDs and troubleshooting failed DIMMs, see "Systems Insight Display LEDs
and internal health LED combinations (on page 15)."

Hot-plug SAS hard drive options

When adding hard drives to the server, observe the following general guidelines:
Bank A
Bank B
1A and 2A
3B and 4B
1st
2nd
1st
3rd
Always install memory in pairs of two identical DIMMs.
"Remove the air
Bank C
5C and 6C
2nd
baffle" on page 25).
Hardware options installation 47
Bank D
7D and 8D
4th

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant dl385 generation 2

Table of Contents