Blower Assemblies

50
Unplugging a single power cable can power down the entire
CAUTION
switch, depending on which power supply slots contain power supplies.
Two power cords are provided to connect the switch chassis to the PDUs.
PDU and country specific cables are ordered separately.
The AC power switches light up green when on.
The switch is cooled by three blower assemblies located on the blower
assembly side of the chassis. The air enters through the vents on the blower
assembly side of the chassis and exits from the vent in the top of the port
side of the chassis. The chassis requires a minimum airflow of 350 cubic
feet per minute. This requires a minimum of two blower assemblies
operating at all times.
The blower assemblies are hot-swappable. If more than one blower
assembly must be removed at the same time, turn off the switch to prevent
overheating.
The HP StorageWorks Core Switch 2/64 requires a minimum of
WARNING
two functioning blower assemblies during operation. To ensure continuous
adequate cooling, maintain three operating blower assemblies at all times
except for the brief period when replacing a blower assembly.
The HP StorageWorks Core Switch 2/64 16-port cards automatically shut
down if the temperature range is exceeded.
Disassembling any part of the blower assembly voids the part
CAUTION
warranty and regulatory certifications. There are no user-serviceable parts
inside the blower assembly.
To determine the status of a blower assembly:
1. Check the LED indicators on the blower assembly.