HP StorageWorks 2/32 - SAN Switch Release Note page 59

San switch 2/32 version 4.0.2b release notes
Hide thumbs Also See for StorageWorks 2/32 - SAN Switch:
Table of Contents

Advertisement

5. Logout from the DCL prompt. This will return you to the Installation Menu.
Now select Option 1 from the installation menu to install/upgrade the operating
system as you normally would.
OpenVMS Path Failback
In very specific configurations utilizing multiple OpenVMS hosts connected to
multiple ports of an HP StorageWorks SAN Switch 2/32, it is possible that not all
paths will re-establish to a switch after a failover/failback failure scenario. In all
cases where a path failure occurs, initial path failover to an alternate path occurs
as expected, with no loss of data. Once the initial failed path is repaired however,
it is possible under certain rare conditions, for the failback sequence to the
repaired path to be unsuccessful.
HP believes the likelihood of occurrence is extremely low and has only
encountered this condition under extensive, multiple repeated failover/failback
test sequences. This condition is expected to be corrected in a future release.
Note:
verify access is available on all configured paths. HP further recommends that cabling
for multiple paths follow the high availability cabling guidelines published in the
StorageWorks SAN Design Reference Guide
multi-path configuration to a different Fibre Channel switch.
Monitoring Status of Device Paths
Periodically use the show dev/full or show dev/multi command to
display status of device paths. If a path is determined to be missing, follow the
procedure below to restore the path.
Restoring Missing Device Paths
Restore device paths in one of two ways:
SAN switch 2/32 Version 4.0.2b Release Notes
$$$ LOGOUT
HP strongly recommends that customers periodically monitor device status to
By disabling/enabling the affected switch port, or
By disconnecting/reconnecting the affected HBA cable at the HBA or at the
switch port.
, which specifies to connect each path in a
Known Issues
HP
59