Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X on Windows systems
16. Complete the following steps on the Server Port Configuration screen.
17. Select one of the following options on the SAN Size screen (for Pure Fabric OS fabrics only):
18. Click Next.
DCFM Installation, Migration, and Transition Guide
53-1001360-01
NOTE
Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server.
FIGURE 48
Server Port Configuration screen
a. Enter a port number in the Syslog Port # field (default is 514).
NOTE
If the default syslog port number is already in use, you will not receive any syslog
messages from the device.
b. Select the SSL Enabled check box to enable SSL.
c.
Enter a port number in the Web Server Port # field (default is 443 if SSL Enabled is
selected; otherwise, the default is 80).
d. Enter a port number in the SNMP Port # field (default is 162).
e. Enter a port number in the Starting Port # field (default is 24600).
NOTE
The server requires 16 consecutive free ports beginning with the starting port number.
f.
Click Next.
If you enter a Syslog port number already in use, a message displays. Click OK to close the
message. Edit the Syslog port number and click Next.
If you enter a port number already in use, a Warning displays beneath the associated port
number field. Edit that port number and click Next.
Small (managing up to 2000 ports, 1-20 domains)
Medium (managing up to 5000 ports, 21-60 domains)
Large (managing up to 9000 ports, 61-120 domains)
2
107