Fcu Error Codes For Windows Systems - HP StorageWorks P9000 User Manual

Data exchange user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 67
fcudata.prm.log).
2000/Windows NT systems and provides instructions for resolving each error condition.
NOTE:
Error codes with a plus value are system errors. Windows systems system error codes are defined in
the errno.h file attached with Microsoft Visual C++.
Table 67 FCU Error Codes for Windows Systems
Error
Error Message and Description
Code
Parameter definition file: Open error
-100
An error occurred when opening the
parameter definition file.
Parameter: Count error
-101
An error is detected in the parameter
count.
Parameter: Direction error
-102
The data transfer direction is not correct.
Parameter: Mainframe file name error
-103
The mainframe file name is not correct.
Parameter: Open system file name error
-104
The open system file name is not correct.
Parameter: Code conversion error
-105
The code conversion setting is not
correct.
Parameter: Padding error
-106
The padding setting is not correct.
Parameter: Delimiter error
-107
The delimiter setting is not correct.
Parameter: Add parameter error
-108
The delimiter setting is not correct.
Parameter: Empty duplication error
-109
More than one empty setting is
specified.
164
Troubleshooting
on page 164 lists and describes the FCU error codes for Windows
Recommended Actions
Make sure that the parameter definition file was
created correctly. If the parameter definition file
was created correctly, check the system error.
Make sure that the parameter count is correct.
Make sure that the direction is specified cor-
rectly as mto or otm.
Make sure that the mainframe file name is set
correctly.
Make sure that the open system file name is set
correctly.
Make sure that the code conversion option is
specified as EA, EcA, No, or File_name (of your
code conversion table). This error may also be
reported if you mix 3390/3380 and OPEN-x
devices in the same Data Exchange volume
definition file.
Make sure that the padding option is specified
as Yes or No.
Make sure that the delimiter option is specified
as CRLF or No.
If you are adding delimiters for Windows sys-
tems, make sure that the delimiter option is
specified as CRLF (not just CR or LF).
Specify only one empty setting.