Error
Error Message and Description
Code
Parameter file: PADDING error
-108
The padding option specified in the
parameter definition file is not valid.
Parameter file: DELIMITER error
-109
The delimiter option specified in the
parameter definition file is not valid.
Parameter file: Open error
-110*
An error occurred when opening and
outputting the parameter definition file.
Parameter file: Write error
-111
An error occurred when writing to the
parameter definition file.
Parameter file: Close error
-112
An error occurred when closing the
parameter definition file.
Parameter: No input file name
-114
The input file name was not specified.
Parameter: VSN error
-115
The specified VSN is not correct.
Parameter: Input file name error
-116
The specified input file name is not
correct.
Parameter: Dataset name error
-117
The specified input dataset name is not
correct.
Parameter: Output file name error
-118
The specified output file name is
incorrect.
Input file: Open error
An error occurred when acquiring the
-119*
dataset attribute information for the input
file.
Make sure that the padding is specified as either
Yes or No.
Make sure that the delimiter is specified as either
CR, LF, or No.
Display the system error code using the Help-
Error command. See the OS user manual for
information on system errors.
Display the system error code using the Help-
Error command. See the OS user manual for
information on system errors.
Display the system error code using the Help-
Error command. See the OS user manual for
information on system errors.
Make sure to specify the input file name.
Make sure that the specified VSN matches the
actual VSN. Make sure that the VSN is separ-
ated from the dataset name by a colon (:).
Make sure that the specified file name matches
the actual file name.
Make sure that the specified dataset name
matches the actual dataset name.
Make sure that the specified output file name
matches the actual output file name.
Display the error code using the Help-Error
command. If a FAL error code is displayed, see
Table 65
displayed, see the OS user manual. For ex-
ample, if a partition name does not match the
partition name in the volume definition file, sys-
tem error code 6 (No such device) is displayed.