Preparing For Data Exchange Operations; System Requirements; Data Exchange Version Support For Storage Systems - HP StorageWorks P9000 User Manual

Data exchange user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

3 Preparing for Data Exchange Operations

This chapter describes the system and volume configuration requirements to run and operate Data
Exchange. It also provides instructions on how to install Data Exchange.
• System
Requirements, page 49
• Installing and Configuring the Data Exchange
• Installing the Data Exchange
• Entering the Data Exchange License Key
• Creating FXoto Volumes Using the FMT
• Creating the Data Exchange Volume Definition
• Verifying Mainframe Dataset
• Allocating FXoto Intermediate

System Requirements

The user should examine existing data exchange needs carefully, especially the desired number of
Data Exchange volumes to be installed and configured, prior to the storage system configuration. This
is due to the possible need to reconfigure and reformat entire array groups, depending on the
microcode level of the storage system.
The system requirements for Data Exchange are:
Data Exchange software for the applicable open-system platforms. This revision of the HP Storage-
Works Data Exchange Software User s Guide covers Data Exchange software versions 01-XX-6x
and later. For information on earlier versions, see the previous revisions of this document.
• Data Exchange supports files larger than 2 GB.
• When installing/uninstalling Data Exchange (for 32/64-bit), follow the procedure presented
in this chapter. For 64-bit installation, the Data Exchange program must be version 01–XX–59
or later.
Storage systems:
• FXmto: The storage systems must be configured with -B and/or -A Data Exchange volumes.
• FXotm: The storage systems must be configured with -C and/or -A Data Exchange volumes.
• FXoto: The user can format OPEN-x LUs as FXoto volumes or use -C Data Exchange volumes.
Table 27
models.
Table 27 Data Exchange Version Support for Storage Systems
P9500 Disk Array
XP24000/XP20000 disk array
Software, page 60
Requirements, page 75
Datasets, page 76
on page 49 specifies the Data Exchange version support for the storage system
Storage System
Volumes, page 55
Code, page 64
Utility, page 66
Files, page 71
Data Exchange (32-bit) Ver-
sion
01-06-67 and later
01-05-66 and later
HP StorageWorks P9000 Data Exchange User Guide
Data Exchange (64-bit) Ver-
sion
01-06-67 and later
01-05-66 and later
49

Advertisement

Table of Contents
loading

Table of Contents