HP StorageWorks P9000 User Manual page 122

Data exchange user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

2.
Open the command prompt (DOS Windows) and input the parameters below:
• fcunw [-cl] [param] ( [-v] )
• -cl: Specifies that all the log files for FCU will be cleared before stating FCU.
• param: This parameter is used the as same as (1) in this section for UNIX.
NOTE:
When this parameter is not specified, the file name of the parameter definition file will be
assumed to be fcudata.prm and it will attempt to read the detail parameters from the file.
• -v: This displays the version of fcunw.
NOTE:
This parameter cannot be used with any other parameter simultaneously, as it specifies
versions.
• [Return value] 0: Normal end
• [Return value] 1: Error end.
NOTE:
The fcunw command requires the parameter definition file to function properly. If there is no parameter
definition file or if there is an incorrect parameter in the parameter definition file, the following message
will be displayed:
[A parameter definition file doesn't exist, or it is illegal.]