Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[PROV],Set Host Mode,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Port,HostGrpID,Mode,Option[0:31],Option[32:63],Option[64:95]}
=[{XX,0xXXX,0x00,0xXXXXXXXX,0xXXXXXXXX,0xXXXXXXXX},{XX,0xXXX,
0x4F,0xXXXXXXXX,0xXXXXXXXX,0xXXXXXXXX}],Num. of Host Groups=2
Detailed information
Item
Port
HostGrpID
Mode
Option[0:31]
Option[32:63]
Option[64:95]
Num. of Host Groups
[PROV] Set Security Switch
This log is output when LUN Manager operation is performed using Configuration File Loader.
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[PROV],Set Security Switch,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Port,Switch}=[{XX,Disable},{XX,Enable}],Num. of Ports=2
Detailed information
Item
Port
Switch
Num. of Ports
[PROV] Set SSID
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[PROV],Set SSID,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{SSID,LDKC:CU:LDEV}
=[{0xXXXX,0xXX:0xXX:0xXX},{0xXXXX,0xXX:0xXX:0xXX}],
Num. of SSIDs=2
142 Audit log examples
Description
The name of the port to which the host group belongs.
The host group number.
The host mode set. See the HP StorageWorks P9000 Provisioning for Open Systems User Guide
for the description of the host mode number.
The specified host mode option. The host mode options are configured with 96 units of 0 to 95,
and are divided into 32 units to output. See
relation of output values and host mode option.
See the HP StorageWorks P9000 Provisioning for Open Systems User Guide for the description
of the host mode number.
The number of host groups that the host mode setting is changed.
Description
The name of the port where the LUN security setting is changed.
Indicates whether the LUN security setting is enabled or disabled.
Disable or Enable will appear.
The number of ports where the LUN security setting is changed.
Table 12 (page 123)
to
Table 14 (page 124)
for the