Patrol Read-Related Controller Properties; Set Patrol Read Options; Set Patrol Read Delay Interval; Bios-Related Properties - Lenovo ThinkServer RD330 Software User's Manual

Megaraid sas software user guide
Hide thumbs Also See for ThinkServer RD330:
Table of Contents

Advertisement

MegaRAID SAS Software User Guide
5.9
Patrol Read-Related
Controller Properties
5.9.1

Set Patrol Read Options

Table 49: Set Patrol Read Options
Convention
MegaCli –AdpPR –Dsbl|EnblAuto|EnblMan|Start|Stop|Info | {-SetStartTime yyyymmdd hh} |
maxConcurrentPD -aN| -a0,1,2|-aALL
Description
Sets Patrol Read options on a single controller, multiple controllers, or all controllers:
-Dsbl: Disables Patrol Read for the selected controller(s).
-EnblAuto: Enables Patrol Read automatically for the selected controller(s).
This means Patrol Read will start automatically after the controller initialization is complete.
-EnblMan: Enables Patrol Read manually for the selected controller(s). This means that Patrol Read does not start
automatically; it has to be started manually by selecting the Start command.
-Start: Starts Patrol Read for the selected controller(s).
-Stop: Stops Patrol Read for the selected controller(s).
-Info: Displays the following Patrol Read information for the selected controller(s):
• Patrol Read operation mode
• Patrol Read execution delay value
• Patrol Read status
SetStartTime yyyymmdd hh: Set the start time for the patrol read in year/month/day format.
maxConcurrentPD: Sets the maximum number of concurrent drives that patrol read runs on.
5.9.2

Set Patrol Read Delay Interval

5.10

BIOS-Related Properties

5.10.1
Set or Display Bootable Virtual
Drive ID
You can use the commands in this section to select the settings for Patrol Read. A Patrol
Read scans the system for possible drive errors that could lead to drive failure, then
takes action to correct the errors. The goal is to protect data integrity by detecting drive
failure before the failure can damage data. The corrective actions depend on the virtual
drive configuration and the type of errors. Patrol Read affects performance; the more
iterations there are, the greater the impact.
Use the command in the following table on the selected controller(s) to set the Patrol
Read options.
Use the command in the following table on the selected controller(s) to set the time
between Patrol Read iterations.
Table 50: Set Patrol Read Delay Interval
Convention
MegaCli –AdpPRSetDelay –Val -aN|-a0,1,2|-aALL
Description
Sets the time between Patrol Read iterations on a single controller, multiple
controllers, or all controllers:
-Val: Sets delay time between Patrol Read iterations. The value is time of
delay in hours. A value of zero means no delay and an immediate restart.
You can use the commands in this section to select the settings for BIOS-related
options.
Use the command in the following table to set or display the ID of the bootable virtual
drive.
Chapter 5: MegaRAID Command Tool
|

Patrol Read-Related Controller Properties

Page 187