Drive Group; Virtual Drive; Fault Tolerance - Lenovo ThinkServer RD330 Software User's Manual

Megaraid sas software user guide
Hide thumbs Also See for ThinkServer RD330:
Table of Contents

Advertisement

|
Chapter 2: Introduction to RAID
Components and Features
2.4.1

Drive Group

2.4.2

Virtual Drive

2.4.3

Fault Tolerance

2.4.3.1
Multipathing
Page 22
A drive group is a group of physical drives. These drives are managed in partitions
known as virtual drives.
A virtual drive is a partition in a drive group that is made up of contiguous data
segments on the drives. A virtual drive can consist of an entire drive group, more than
one entire drive group, a part of a drive group, parts of more than one drive group, or a
combination of any two of these conditions.
Fault tolerance is the capability of the subsystem to undergo a drive failure or failures
without compromising data integrity, and processing capability. The RAID controller
provides this support through redundant drive groups in RAID levels 1, 5, 6, 10, 50, and
60. The system can still work properly even with drive failure in a drive group, though
performance can be degraded to some extent.
In a span of RAID 1 drive groups, each RAID 1 drive group has two drives and can
tolerate one drive failure. The span of RAID 1 drive groups can contain up to 32 drives,
and tolerate up to 16 drive failures - one in each drive group. A RAID 5 drive group can
tolerate one drive failure in each RAID 5 drive group. A RAID 6 drive group can tolerate
up to two drive failures.
Each spanned RAID 10 virtual drive can tolerate multiple drive failures, as long as each
failure is in a separate drive group. A RAID 50 virtual drive can tolerate two drive
failures, as long as each failure is in a separate drive group. RAID 60 drive groups can
tolerate up to two drive failures in each drive group.
NOTE: RAID level 0 is not fault tolerant. If a drive in a RAID 0 drive group fails, the whole
virtual drive (all drives associated with the virtual drive) fails.
Fault tolerance is often associated with system availability because it allows the system
to be available during the failures. However, this means that it is also important for the
system to be available during the repair of the problem.
A hot spare is an unused drive that, in case of a disk failure in a redundant RAID drive
group, can be used to rebuild the data and re-establish redundancy. After the hot spare
is automatically moved into the RAID drive group, the data is automatically rebuilt on
the hot spare drive. The RAID drive group continues to handle requests while the
rebuild occurs.
Auto-rebuild allows a failed drive to be replaced and the data automatically rebuilt by
"hot-swapping" the drive in the same drive bay. The RAID drive group continues to
handle requests while the rebuild occurs.
The firmware provides support for detecting and using multiple paths from the RAID
controllers to the SAS devices that are in enclosures. Devices connected to enclosures
have multiple paths to them. With redundant paths to the same port of a device, if one
path fails, another path can be used to communicate between the controller and the
device. Using multiple paths with load balancing, instead of a single path, can increase
reliability through redundancy.
MegaRAID SAS Software User Guide

Advertisement

Table of Contents
loading

Table of Contents