Cf_Nzred Command; Cf_Image Command - Sanyo PLC-WK2500 - 2500 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WK2500 - 2500 Lumens:
Table of Contents

Advertisement

PLC-WK2500
Expand Serial Command Functional Specifications

8.4.11 CF_NZRED Command

Command
"CF_NZRED_%1"[CR]
"OFF" ------- Cancel Noise Reduction
"L1" --------- Noise Reduction for moving image
%1
"L2" --------- Noise Reduction for still image
"UP" --------------- The same operation as pressing Up key or Left key
"DN" ----------------The same operation as pressing Down key or Right key
Noise Reduction based on frame correlation
Select L1 or L2 depending on motion detection
L2 is more effective in reducing noise than L1, however, L2 can have a blur in
moving image
Details
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF. (The value is held in Suspend
mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.4.12

CF_IMAGE Command

Command
"CF_IMAGE_%1"[CR]
"DYNAMIC" ------ Dynamic (Fixed value to enable projection with a sharp, powerful
"STAND" ---------- Standard (Image adjust value is set to factory default)
"REAL" ------------ Real (Fixed value to display graphic image with natural tone)
"CINEMA" -------- Cinema (Fixed value to focus on tone reproduction for movie)
"BLACKBOARD" – Blackboard (Fixed value to project image onto green-colored
%1
"COLORBOARD " – Colorboard(Fixed value to project image onto colored board)
"CUSTOM1" ----- Image1 (the value set and stored by a user)
"CUSTOM2" ----- Image2 (the value set and stored by a user)
"CUSTOM3" ----- Image3 (the value set and stored by a user)
"CUSTOM4" ----- Image4 (the value set and stored by a user)
Select Image Mode
Parameter "CUSTOM1" to "CUSTOM4" is the same as "Image1" to "Image4"
displayed when selecting Image on OSD menu.
Details
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
picture tone)
blackboard)
blackboard)
"000"[CR]
"Error Code"[CR]
21 / 74

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wk2500

Table of Contents