When using pathinfo in MetaSAN, where the destination domain
queried overlaps with intermediate hop/domain, output of this com-
mand is not accurate.
Date cmd should be rejected on non-Default LS.
"Updating Flash" Console Message is seen on all Fabric OS Switches
in Fabric during configupload on Single Fabric OS Switch in a In-
teropmode 2 fabric.
Block user from configuring QoS on 6-port 10Gb ISL blade.
Inappropriate error message from configuredownload in VF mode
and LSAN zone tag /LSAN matrix is not cleared when the config file
contains no entry for them.
In one rare case, zoneobjectrename command failed without
reason.
Changing configuration using configure or configDownload when
systemVerification is executed could lock out the systemVeri-
fication from being executed subsequently.
Channel definition errors; time out on QSA Response due to excessive
link incidents.
The ifNumber does not match the number of entries in the ifTable for
the logical switches with LISL.
Newly created LS should inherit NTP server setting of Default LS.
Allowed to add a F_Port TT Monitor to mirror port, however no counters
display.
Virtual nodes on the same switch port may not be able to communicate
due to missing RSCNs and the CAM not be programmed. This is not
a likely scenario.
Command portcfgdefault performed on an internal F_Port will
convert that F_Port into an N_Port.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Change date only on the default
switch.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Please ignore the error message and
use CLI to clear LSAN tag and LSAN
binding.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not update the configuration when
systemVerification is running. If user
accidentally changes configuration
when the command was executing,
use "burninlevel 0" to recover from
this situation.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Don't use date command in
non-default logical swtich.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Toggle the physical port.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
When the system is working well,
save that configuration somewhere so
that it can be reapplied instead of
relying on portcfgdefault.