Node descriptors are not shown for M-EOS switch in DCFM when using
a Fabric OS switch as the seed switch.
Get error CHASSIS, ERROR, SYS, FPGA error, DECRYPT_DECOM-
PRESS_FAIL : Cmd 0x932b6000, Myxid 0x6b3, PI/PT
0x41d00/0x41acc, Lun 0, PIOxid 0x131 PTRxid and the tape drive
is brought offline when labling a tape using TSM application.
[NSM] show message-stats command is missing mark option.
Detail view of WebTools Name Server Information should be greyed
out if no window will open.
Ports were found disabled after enabling Virtual Fabric (VF) through
DCFM on 8/40 SAN Switch.
Fabric watch: (java.lang.illegalArgumentException:Invalid logid) error
message box will appear when selecting Configuration report sub-tab
under Threshold configuration tab.
Port Movement from DCFM should be All-or-nothing behavior.
SCPD computes incorrect FCR domain ID in McDATA Fabric Mode
(interopMode 2).
No external Ethernet port association for pre-FIP FLOGI/FDISC unicast
frames.
Observed frame drops and IFCCs with lossless feature.
Encryption SAN Switch panic because KACd memory leak with multiple
get key operation.
FR zones cannot be created when defzone is set to "allaccess."
The lfcfg command shows incorrect data.
Switch Admin: Policies which are not chosen are showned in confirm-
ation page of ACL Policy configuration wizard.
When attempting to swap ports from the GUI, the operation may fail
due to HTTP 500 error.
Agd aborted due to *** glibc detected *** free(): invalid next size
(fast).
DWDM link unable to sync up before port is enabled at correct speed.
Bad SFP triggered i2c access cause issues on port/slot disaplay and
cpu load on 4/256 SAN Director.
Cryptocfg show transshow when issued without any outstanding
transactions displayed Operation "failed" with an incorrect cause.
60
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Erase the media outside of the
Encryption SAN Switch and then
continue on with label.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Set defzone to "noaccess."
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0