Sometimes config file downloaded may cause the configdownload
command to crash.
After changing FID on HP StorageWorks 8/40 SAN Switch and then
performing switchenable, switchdisable, observed ASSERT.
HA cluster member node, HP StorageWorks Encryption SAN Switch
faults as a result of slot power cycling its HA cluster peer (HP Storage-
Works DC Encryption FC Blade).
IPL file is not getting updated, when a PDCM matrix is activated using
WebTools with Active=Save Mode checked.
Fabric Watch failed to initialize on fully populated HP StorageWorks
DC SAN Backbone Director.
Memory leak when querying connUnitPortFCId in Access Gateway
(AG) mode and also when querying FcFeModuleName.
Occasionally during the firmware upgrade process, the 1250 processor
is still rebooting when the FCR routes are being processed, resulting
in missing FCR routes and an inability to route traffic across VEX ports.
CUP Port present CU-Busy on one path and never sending CU-End to
clear busy.
In B2E routed environment, when user executes pathinfo command
in BB querying for xlate domain, the switch may panic.
Observed kernel panic on a DC SAN Backbone Director in RTE module.
Switches leaking memory slowly over extended period while being
managed by DCFM.
Switchdisabling all switches in the fabric causing all HP Storage-
Works 4/256 SAN Director switches Out of Memory: Killed
process 2337 (iswitchd).
License problem observed after configdownload and QoS license
was checked for 4G platforms at CLI.
Unable to configure ports using configdownload.
Portcams and NS zonemembership data are missing for hard-zoned
ports.
Software was not enforcing a mandatory switch disable before config-
uring the backbone Fabric ID.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Disable the switch and then attempt
configdownload.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not disable a switch immediately
after enabling if it's coming up with
a new FID for the first time. Wait for
at least 10 seconds before issuing
switchdisable.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Reboot the Encryption SAN Switch.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Avoid querying FcFeModuleName
or (connUnitPortFCId in AG
mode) MIB to avoid memory leak.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0