HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 68

Hp storageworks fabric os 6.3.0c release notes (5697-0301, january 2010)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

EE monitor counter is not incrementing after firmware upgrade to 6.2.0.
ISL monitor total transmit and number of destination domains monitored
counters show 0 when traffic is running thru this ISL.
SNMP: The swNs Table does not list all the name server entries.
Interopmode 2 - Value other than 0 or 1 in configdownload file will
enable default zone; I was expecting an error message.
IP monitor shows number of SCSI frames after deleting a SCSI filter
monitor and adding IP monitor on the same port.
Onboard Administrator used to manage 8 Gb SAN Switch for
BladeSystem c-Class is not able to read the switchname.
Statsclear does not clear porterrshow statistic data for field
"link fail " on 6-port 10Gb/s ISL blade.
"Cyptocfg --show -tapepool -all -stat" returns "Operation failed:" the
first time it's issued but displays valid output when immediately re-is-
sued.
With virtual fabric enabled, when no EE is present, cryptocfg show
localEE returns "EE detection aborted: IPC Failure".
A LUN with encryption mode: cleartext and encryption format: Brcd
Native, fails to read DF_Compatible tape media.
After repeatedly deleting and adding partitions, creating a new parti-
tion resulted in an ASSERT at "file = .../bccb/lib/utils/register.c, line
= 115, user mode" and termination of ficud.
SR Request for IBM PMH 85437,000,738 - HK Monetary.
Unable to clear Port Name from screen " Edit CUP Port Connectivity
Configuration."
SNMP changes required to better support snmp mib.
Rare Instances of warm recovery failure during upgrade due to small
timing window in library used by some services.
Fabstateshow log wrapping overwrites useful fabstate data on the
switch when interoperating with McDATA switches.
68
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Delete and re-install EE Monitors.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Switch name can be displayed from
Fabric OS CLI command -
switchname.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Re-issue the CLI.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Configure the LUN with encryption
mode:encrypt & encryption
format:DF_Compatible and restore
the files from the tape media.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Issue an additional reboot or
hafailover.
Fixed in Fabric OS 6.3.0