Switch Admin: Proper error message should pop up when disabling
of FCoE in a VLAN fails.
Switch panic when supportsave read invalid data on GE ports without
FC Fastwrite enabled.
Firmware downgrade from Fabric OS 6.2.0 to 6.1.0 sometimes causes
an unresponsive console, which requires a switch power cycle to re-
cover.
Rekeyed LUNs are in "Not Ready (Getting key from archive)" state
when the key vault goes down and does not recover.
WebTools Zone Admin "Add member" button is always disabled.
In non-VF mode on DC SAN Director, after removing other filters (EE
and F_Port TT) and enabling Fabric mode TopTalkers, the flow values
are not reliable.
HA Failover on DC SAN Director caused: Need to reboot the system
for recovery, reason: System bring up timed out.
In Access gateway mode,Port swap and Enable/Disable NPIV option
is enabled in WebTools.
As DCFM polling LUNs, the memory usage for weblinker is increased.
FDMI: fdmid crashes when a brocade HBA with virtual ports is connec-
ted to a 4/256 SAN Director.
Brocade 8000 firmware download hot code load shows no identifier
in the HTML page.
Unable to activate a new PDCM Matrix with WebTools.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
View the switch events to determine
the reason for failure.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change: 1.
Avoid using firmwaredownload -sb
i.e. avoid auto-reboot. Use
firmwaredownload -s and then do a
manual reboot. 2. Need to power
cycle the switch. The switch functions
properly after power cycle with
normal access to the telnet session.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Add members with the "Add other"
button.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Mannually block and unblock an
E_Port to rebuild the fabric.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Logout all the devices registered their
HBA info and log them in after the
fabric is stable.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Activate the same PDCM Matrix from
WebTools, with "Active=Save Mode"
checked from 'Edit CUP Port
Connectivity Configuration' window.
HP StorageWorks Fabric OS 6.3.0c Release Notes
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents