HP A7533A - Brocade 4Gb SAN Switch Base Release Note page 59

Hp storageworks fabric os 6.3.0c release notes (5697-0301, january 2010)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Fabric Watch: The FRU status does not auto-refresh after removal/in-
sertion of the FRU.
FCoE frames from any SMAC are incorrectly passed to the FC side.
Switchname mismatch between GUI display and CLI.
Issues with Brocade MIB objects with ifSpeed returns wrong value,
ifOutUcastPkts, ipAdEntReasmMaxSize, ipRouteAge, ipRoutingDiscards,
snmpSilentDrops, snmpProxyDrops needs to be documented.
After cfgdefault and migration from Interopmode 0 to Interopmode 2,
all switches are setting idid bit in ESA, when idid is not enabled.
Syshutdown: execution of command in current build yields only "this
is a unknown system" string on session consoles.
Cannot use fwconfigure to view the information on internal F/FL
ports (Copper).
Internal routes are not being configured.
Port state mismatch on internal copper ports on Embedded platforms
between switchshow and portcfgshow's PersistentDisable flag.
The Distribute Policy option is missing from the SCC and DCC tabs in
web mgmt.
Supportshow cli command output should complete without having
to hit CR several times.
FVT: lun state never changed from write metadata to enable after GE
port enable.
Urouteshow will lag for several seconds at a time while displaying
the route info.
A LUN gets stuck in the Internal EE LUN State: Read Only (Internal
metadata key is in RO state).
After changing to non-FCS primary policy, web client can still activate
ACL policy.
WebTools shows high CPU usage (~80%) when port configuration
operation is performed in DCX.
FICON fcip block count mismatch on read emulation.
Unable to enable FMS Mode using WebTools on a DC04 SAN Director
with a 48 port blade.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Close and re-open Fabric Watch.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Fabric can be merged by disabling
the switches and setting idid mode in
the switch configurations, then
bringing the switches online. This
option is applicable only in the event
the user wishes to merge the switch
to a fabric that also has idid set.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
HP StorageWorks Fabric OS 6.3.0c Release Notes
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents