Node descriptors are missing for DC SAN Director and DC04 SAN
Director.
Tape pipelining code begins to randomly send only data frames in an
exchange to tape drive.
Partitioned DC04 SAN Director panicked after reset allegiance issued
by multiple hosts.
Rolling ASSERT+PANIC on DC SAN Director with DC Switch Encryption
blade faulty when going from 6.1.2 to 6.2.0d.
Portswap not working for ports 32-47 on 48 port blade.
VI to PT routes are deleted following portdisable and portenable
on a 48–port 4Gb blade.
2408 FCoE Converged Network switch freezes with jumbo frame
blast.
FDMI Database information not showing proper information after dis-
abling the port in AG that is connected to HBA.
Host with Fibrechannel Fastwrite (FCFW) enabled has problems with
port disable/enable of HBA ports.
Switch Kernel panics when performing VMware VMotion (vport migra-
tion).
While rekey operations are in progress, disrupting the I/O sync link
causes rekey operations to hang.
In an atypical test configuration, system reboot observed on one of
two 2408 FCoE Converged Network switches configured as point-to-
point FC connections.
Port Fencing - E_Port Class Link Resets are not fencing.
There is a small timing window that devices might send PLOGI earlier
than route is setup and cause PLOGI drop in single switch fabric.
2408 FCoE Converged Network switch has a rolling reboot when
deleting the active fcoe logincfg from conflicting logingroup database.
After rebooting one Encryption SAN Switch of a HAC that has con-
nectivity to the physical targets and initiators, all the crypto targets are
lost in the HAC cluster.
IPAD-5000 messages with error code "105" showing up on most
platforms in AG fabrics. Possible Memory Leak scenarios.
RLIRs with LOL is being generated on 8 Gb channels during CEC IML
Fail to label tape w/ error: ERROR, SYS, Crypto tape receives service
failure in tape_cmd_pre_execution_scsi_chk: PI BLK size > RBL, 0x0,
tape_util.c, line: 5002.
User entered FRU number via CLI is not being modified.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0