VCM don't have GUI capability to change SNMP read community
configuration.
8/80 SAN Switch: Removing any power supply FRU causes fans to
speed up for a short period (which is not expected).
The SFP parameters are not returning for the ports which are under
the logical switches other than the default logical switch.
ptsupportshow -all does not function properly.
WEBLINKERFCGD core files after weekend SAK/IRNDUP run on DC04
SAN Director.
Applications cannot distinguish between Multiprotocol Router Blade
and Core blades on DC SAN Director using SNMP. Need to add two
new FRU classes: "coreblade" and "applicationblade" class.
Switch panic in ficon enviormnet when blocking/unblocking E-Port due
to RNID data count is incorrect.
Switch Admin: when user moves to a different tab without applying
changes, no warning is displayed.
Performance Monitoring: Error message is shown when launching
SCSI Read/Write on a LUN Per port graph.
Enabled minimum Fabric OS support for DWDM-SFP port media.
Re-keys are getting stuck.
DC SAN Director: configdownload: simple upload/download
(switch enabled) complaining about FID 128 and will not download
with switch enabled.
Switch Admin: CEE: NPE is shown in error message when user applies
a new FCoE login group (with Login management disabled.)
pertperfshow does not display decimal data if overall throughput
exceeds 10Gbps.
A switch restart causes random ICL E-Ports to come up "segmented."
When running FCoE traffic, debug_csock_read_header failures mes-
sage displays.
58
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Specify the slot number for which the
command is directed. For example,
ptsupportshow 1 -all command
to see all ports on blade 1.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
User has to execute the CLI command
fcoelogincfg before using
WebTools to create the login groups.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Port toggle when it gets segmented.
Fixed in Fabric OS 6.3.0