Configuring Vmps - Cisco 2950G 24 - Catalyst Switch Software Configuration Manual

Desktop switch
Hide thumbs Also See for 2950G 24 - Catalyst Switch:
Table of Contents

Advertisement

Configuring VMPS

Beginning in privileged EXEC mode, follow these steps to configure the network shown in
Command
Step 1
configure terminal
Step 2
interface fastethernet 0/1
Step 3
switchport mode trunk
Step 4
exit
Step 5
Step 6
end
Step 7
show running-config
Step 8
show vlan
Step 9
configure terminal
Step 10
interface fastethernet 0/1
Step 11
spanning-tree vlan 2 cost 30
Step 12
spanning-tree vlan 3 cost 30
Step 13
spanning-tree vlan 4 cost 30
Step 14
end
Step 15
Step 16
exit
Step 17
show running-config
Step 18
copy running-config startup-config
Configuring VMPS
The switch cannot be a VMPS server but can act as a client to the VMPS and communicate with it
through the VLAN Query Protocol (VQP). VMPS dynamically assigns dynamic access port VLAN
membership.
This section includes this information about configuring VMPS:
Catalyst 2950 Desktop Switch Software Configuration Guide
14-24
"Understanding VMPS" section on page 14-25
"Default VMPS Configuration" section on page 14-27
"VMPS Configuration Guidelines" section on page 14-28
"Configuring the VMPS Client" section on page 14-28
Purpose
Enter global configuration mode on Switch 1.
Enter interface configuration mode, and define Fast Ethernet port 0/1 as
the interface to be configured as a trunk.
Configure the port as a trunk port.
Return to global configuration mode.
Repeat Steps 2 through 4 on Switch 1 interface Fast Ethernet 0/2.
Return to privileged EXEC mode.
Verify your entries.
In the display, make sure that interfaces Fast Ethernet 0/1 and Fast
Ethernet 0/2 are configured as trunk ports.
When the trunk links come up, Switch 1 receives the VTP information
from the other switches. Verify that Switch 1 has learned the VLAN
configuration.
Enter global configuration mode.
Enter interface configuration mode, and define Fast Ethernet port 0/1 as
the interface to set the STP cost.
Set the spanning-tree path cost to 30 for VLAN 2.
Set the spanning-tree path cost to 30 for VLAN 3.
Set the spanning-tree path cost to 30 for VLAN 4.
Return to global configuration mode.
Repeat Steps 9 through 11 on Switch 1 interface Fast Ethernet 0/2, and
set the spanning-tree path cost to 30 for VLANs 8, 9, and 10.
Return to privileged EXEC mode.
Verify your entries.
In the display, verify that the path costs are set correctly for interfaces
Fast Ethernet 0/1 and 0/2.
(Optional) Save your entries in the configuration file.
Chapter 14
Configuring VLANs
Figure
14-4:
78-14982-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 2950

Table of Contents