Beginning in privileged EXEC mode, follow these steps to configure the network shown in
Command
Step 1
configure terminal
Step 2
interface fastethernet 0/1
Step 3
switchport mode trunk
Step 4
exit
Step 5
Step 6
end
Step 7
show running-config
Step 8
show vlan
Step 9
configure terminal
Step 10
interface fastethernet 0/1
Step 11
spanning-tree vlan 2-4 cost 30
Step 12
end
Step 13
Step 14
exit
Step 15
show running-config
Step 16
copy running-config startup-config
Configuring VMPS
The switch cannot be a VMPS server but can act as a client to the VMPS and communicate with it
through the VLAN Query Protocol (VQP). VMPS dynamically assigns dynamic access port VLAN
membership. This section includes this information about configuring VMPS:
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
16-24
"Understanding VMPS" section on page 16-25
"Default VMPS Client Configuration" section on page 16-26
"VMPS Configuration Guidelines" section on page 16-26
"Configuring the VMPS Client" section on page 16-27
"Monitoring the VMPS" section on page 16-30
"Troubleshooting Dynamic Port VLAN Membership" section on page 16-30
"VMPS Configuration Example" section on page 16-31
Purpose
Enter global configuration mode on Switch A.
Enter interface configuration mode, and define Fast Ethernet port 0/1as
the interface to be configured as a trunk.
Configure the port as a trunk port.
Return to global configuration mode.
Repeat Steps 2 through 4 on Switch A interface Fast Ethernet 0/2.
Return to privileged EXEC mode.
Verify your entries.
In the display, make sure that interfaces Fast Ethernet 0/1 and Fast
Ethernet 0/2 are configured as trunk ports.
When the trunk links come up, Switch A receives the VTP information
from the other switches. Verify that Switch A has learned the VLAN
configuration.
Enter global configuration mode.
Enter interface configuration mode, and define Fast Ethernet port 0/1 as
the interface to set the STP cost.
Set the spanning-tree path cost to 30 for VLANs 2 through 4.
Return to global configuration mode.
Repeat Steps 9 through 11 on Switch A interface Fast Ethernet 0/2, and
set the spanning-tree path cost to 30 for VLANs 8, 9, and 10.
Return to privileged EXEC mode.
Verify your entries.
In the display, verify that the path costs are set correctly for interfaces
Fast Ethernet 0/1 and 0/2.
(Optional) Save your entries in the configuration file.