Error code/symptom
167-400-001 ISMP: Failed
(ISMP failed to communicate with I/O
board.)
167-400-002 ISMP: Failed
(ISMP failed to communicate with processor
board.)
167-400-003 ISMP: Failed
(ISMP failed to communicate with
processors.)
167-400-004 ISMP: Failed
(ISMP failed to communicate with DIMMs.)
180-XXX-001
(Failed front LED panel test.)
180-XXX-000 (Diagnostics LED failure)
180-XXX-001
(Failed front LED panel test)
180-XXX-002
(Failed diagnostics LED panel test)
180-XXX-003
(Failed system board LED test)
180-XXX-005
(Failed SCSI backplane LED test)
201-XXX-0nn
(Failed memory test.)
201-XXX-Y99
(Multiple DIMM failure, see error text)
202-XXX-001
(Failed system cache test)
202-XXX-002
(Failed system cache test)
202-XXX-003
(Failed system cache test)
FRU/action
I/O board
1. Processor board
2. I/O board
1. Processor board
2. I/O board
3. Microprocessor
1. Processor board
2. I/O board
3. DIMMs
1. Front panel
2. I/O board
Run diagnostics panel LED test for the failing LED.
1. Front bezel with customer interface card
2. System board
System board
System board
1. SCSI storage expansion unit
2. System board
1. Replace DIMM nn, where nn is the DIMM number.
2. System board.
1. Isolate the failing DIMM.
a. Replace a DIMM in bank with a known good DIMM.
b. Rerun memory diagnostic for the failing bank.
c. If test fails, mark replaced DIMM as good DIMM.
d. If test passes, mark replaced DIMM as bad DIMM.
e. If DIMM tested is bad, replace the bad DIMM.
f. If DIMM tested is good, do not replace it.
2. Repeat steps 1a through 1f with other DIMMs in the failing bank
until the error is corrected.
3. If error is not corrected, replace system board.
1. Microprocessor 1
2. System board
1. Microprocessor 2
2. System board
1. Microprocessor 3
2. System board