Note: See Chapter 7, "Parts listing, Type 8839," on page 105 to determine which components should be replaced by
a field service technician.
Error code/symptom
165-198-000 (Service Processor: Aborted)
165-201-000 (Service Processor: Failed)
165-330-000 (Service Processor: Failed)
165-342-000 (Service Processor: Failed)
166-198-000 System Management:
Aborted
(Unable to communicate with ASM. It may
be busy. Run the test again.)
166-201-001 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
166-201-002 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
166-201-003 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
166-201-004 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
166-201-005 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
166-342-000 System Management: Failed
(ASM adapter BIST indicate failed tests.)
166-400-000 System Management: Failed
(ISMP self test result failed tests: x where x
= Flash, RAM, or ROM.)
167-300-XXX ISMP: Failed
(ISMP indicates failure in self test.)
84
BladeCenter HS40 Type 8839: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Rerun the diagnostic test
2. Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3. Power down the blade server, and reseat it in the chassis.
4. System board.
1. Power down blade server and reseat it in chassis.
2. System board.
Update to the latest ROM diagnostic level and retry
1. Ensure latest firmware levels for ASM and BIOS are installed.
2. Power down the blade server, and reseat it in the chassis.
3. System board.
1. Run the diagnostic test again.
2. Correct other error conditions and retry. These include other failed
system management tests and items logged in the System Error
Log of the management module.
3. Power down the blade server, and reseat it in the chassis.
4. System board.
1. DIMMs
2. System board
1. Reseat I2C cable between the operator information card and
the system board.
2. Operator information card.
3. System board.
1. I/O adapter
2. System board
1. SCSI storage expansion unit
2. System board
1. DIMMs
2. Microprocessors
3. System board
1. Ensure the latest firmware levels for Remote Supervisor
Adapter and BIOS are installed.
2. Power down the blade server, and reseat it in the chassis.
3. Remote Supervisor Adapter.
1. Reflash or update firmware for ISMP.
2. System board.
1. Remove and reinstall the blade server in the BladeCenter unit.
2. Reflash or update firmware for ISMP.
3. I/O board.