BATTERY

INSPECTION OF BATTERY
SOLUTION LEVEL
The battery is located under the front seat.
MF (Maintenance Free) battery of airtight
type is used for these motorcycles.
It is not necessary to inspect or supple-
ment battery fluid.
However, have your dealer check the
charging condition of battery periodically.
CAUTION
Do not remove airtight cover as it is a
permanently sealed type battery.
Keep separate from the motorcycle if
not used for a long time to reduce
electric discharge and electric leak-
age.
Remove the
when storing the motorcycle.
WARNING
Never invert the battery cables.
Ensure that the ignition switch is in posi-
tion "OFF" before connecting or discon-
necting the battery, otherwise some
components might damage.
negative terminal
CHECK AND CLEAN OF
BATTERY TERMINAL
Clean the battery terminal when it is dusty
or rusted.
1. Set the ignition switch "OFF" position.
2. Remove the front seat.
3. Check that battery lead wire and termi-
nal.
4. If necessary : disconnect the negative
battery wire first, then disconnect the
positive
Remove the battery.
5. Clean the terminal.
If there is white dust, clean it with warm
water.
6. Connect the battery wires and grease
the terminal lightly.
When reinstalling the battery, be sure to
connect the positive
then connect the negative
wire.
58
battery wire.
battery wire first,