Replacing the Redundant Power Supply
(SR2520SAX/SR2520SAXS and SR2520SAXR/
SR2520SAXSR)
Caution: The power supply is not hot-swappable. Before removing or replacing the power supply,
you must first take the server out of service, turn off all peripheral devices connected to
the system, turn off the system by pressing the power button, and unplug the AC power
cord from the system or wall outlet.
The power supply can be replaced if it fails or if one of the fans that is integrated into it
fails. To replace the power supply, use the following instructions.
1. Observe the safety and ESD precautions at the beginning of this book. See
Information".
2. Power down the server and unplug all peripheral devices and the AC power
cable(s).
3. Remove the server system cover. For instructions, see
Cover".
4. Press the green release latch to disengage the power supply (see letter "A") and
remove the power supply by sliding it out of the system (see letter "B") as shown in
the figure below.

Figure 42. Removing Power Supply Module from the Server System

54
A
B
(SR2520SAX/SR2520SAXS and SR2520SAXR/SR2520SAXSR)
"Removing the System
AF001455
®
Intel
Server System SR2520SA User's Guide