This command stops the HP Data Protector Express service on the local machine.
Using the Microsoft Management Console (MMC):
•
a.
b.
c.
d.
3. Stop the SQL Server service using the SQL Server Enterprise Manager.
Step 2: Rebuild the master database
1. Open a command prompt.
2. Switch to the Program Files\Microsoft SQL Server\80\Tools\Binn directory.
3. Run Rebuildm.exe.
4. In the Rebuild Master dialog box, click Browse.
5. In the Browse for Folder dialog box, select the \Data folder on the SQL Server 2000 compact disc or
in the shared network directory from which SQL Server 2000 was installed, and then click OK.
6. Click Settings. In the Collation Settings dialog box, verify or change settings used for the master
database and all other databases.
Initially, the default collation settings are shown, but these may not match the collation selected
during setup. You can select the same settings used during setup or select new collation settings.
When done, click OK.
7. In the Rebuild Master dialog box, click Rebuild to start the process.
The Rebuild Master utility reinstalls the master database.
Note To continue, you may need to stop a server that is running.
Step 3: Restart SQL Server in single-user mode
1. Open a command prompt.
2. Switch to the Program Files\Microsoft SQL Server\mssql\binn directory.
3. Issue the following command:
sqlservr –c –m
If you are restoring the master database for a named instance, issue the following command instead:
sqlservr –c –m –s name
where name is the name of the named instance.
4. Leave the command prompt open.
Step 4: Restore the master database from the most recent backup
1. Open Data Protector Express (with the service stopped).
2. Create a restore job, selecting only the master database.
3. Run the restore job.
Right-click the My Computer icon and select Manage.
In the left pane of the window, select Services and Applications
In the right pane of the window, locate the HP Data Protector Express service.
Right-click the service and select Stop.
Services.
Need help?
Do you have a question about the BB118BV - StorageWorks Data Protector Express Package and is the answer not in the manual?
Questions and answers