Pulse Generator Inspection; Generator Inspection - DAELIM NS125DLX Service Manual

Table of Contents

Advertisement

Performance Test
● Remove the ignition coil.
● Use a CDI unit to test spark performance of the
ignition coil. If there is no spark from the spark
cap of the spark adaptor, replace coil.
Tools: Spark adaptor
Inspection adaptor
NOTE
• Read the tester manual carefully prior to using
the tester.

Pulse Generator Inspection

● Remove the luggage box. (⇨ 4-5)
● Disconnect the A.C. generator 4P coupler and the
green/white wire connector.
● Measure the resistance between the green/white
and blue/yellow wire.
Standard value: 50-170Ω Ω (20℃ ℃ /68℉ ℉ )
NOTE
• Even if the resistance value slightly deviates from
the standard value, sometimes performance is
not affected. In such case, check all related parts
to determine if the cause of trouble exists in other
areas.
• For information on pulse generator change, refer
to section 8.
A.C. Generator Inspection
● Disconnect the A.C. generator coil wire
(black/red).
● Measure the resistance between the black/red
wire and the earth.
Standard value: 50-350Ω Ω (20℃ ℃ /68℉ ℉ )
NOTE
• Even if the resistance value slightly deviates
from the standard value, sometimes function is
not affected. In such case, check all related pats
to determine if the cause of trouble exists in
other areas.
• Carry out this test with the stator mounted on
the engine.
• The tester measuring range is ×1Ω
CDI Tester
Ignition coil
CDI unit
Generator connector
Ignition System
Adaptor
Ingnition Coil
16-5