DKS 1820 Owner's Manual page 24

Dks 1820 telephone intercom system with call down owner's manual
Table of Contents

Advertisement

1820 Telephone Intercom System
Wiring Detail - Powered RJ-71C / Dual Interface Boards
13
12
Lobby Panel
Doorman Telephone
4
16 Volt, 50 VA UL Listed Transformer.
1
1 2
3
4
Earth Ground.
5
2
Optional Central Office phone line - touch tone, loop start.
3
Doorman / Concierge Telephone (Optional).
4
Lobby panel. Connect additional lobby panels in parallel. Refer to lobby panel installation manual for
5
additional wiring requirements.
Use twisted pair wires for phone connections. 24 AWG up to 800 feet; 22 AWG up to 1600 feet.
6
Decoder board terminals. Used with 1816 systems only.
7
Page 24
8
11
11
12
8
9
10
11
13
12
13
14
15
7
11 12
13
14
15
16
17
18
19
2
6
C.O.
PHN
3
6
INCOMING
C.O. PHN
LINES
14
9
Resident
Telephone
w/ Active
C.O. Line
10
RJ71C phone block. See drawing M1816-065-6 for detail.
Incoming phone lines from Central Office.
Outgoing phone lines to individual apartments.
DoorKing connecting cable.
RS-485 connecting cable.
To additional Line Interface Boards.
Powered RJ-71C phone block P/N 1820-047 for use only with residents
without active Central Office phone service.
12 VDC Regulated power supply.
20
21
22
23 24
16 VAC
PWR
INPUT
1
DOORKING, INC., INGLEWOOD, CA 90301
Title:
1820 Telephone Intercom System
Wiring Detail for Powered RJ-71C / Dual Boards
Date:
4/05
Dwg. No.
12 VDC
Reg
15
Input
Resident
Telephone
without
C.O. Line
A
M1820-065-8
Rev.
1820-065-B-2-06