PDG-DSU30 Expand Serial Command Functional Specifications
9.10.4 CR_BACKGND Command
Command
"CR_BACKGND" [CR]
Details
Get setting status of Screen for no signal
Acceptable
Response
Unacceptable
9.10.5 CR_LOGO Command
Command
"CR_LOGO"[CR]
Details
Get setting status of Logo
Acceptable
Response
%1
Unacceptable
9.10.6 CR_HIGHLAND Command
Command
"CR_HIGHLAND" [CR]
Details
Get status of High;amd.
Acceptable
Correspondence
Unacceptable
9.10.7 CR_ON-STA Command
Command
"CR_ON-STA"[CR]
Details
Get setting status of Direct Power On
Acceptable
Response
%1
Unacceptable
9.10.8 CR_P-MANETIME Command
Command
"CR_P-MANETIME" [CR]
Details
Get value of Power management timer
Acceptable
Correspondence
Unacceptable
"000_%a" [CR]
"BLUE" -------------------- Blue Back is selected
"BLACK" ------------------ Black Back is selected
%a
"RED" --------------------- Red Back is selected
"GREEN" ----------------- Green Back is selected
"WHITE" ------------------ White Back is selected
"Error Code" [CR]
"000_%1"[CR]
"ON" -------------------------- Logo is ON
"OFF" ------------------------ Logo is OFF
"Error Code" [CR]
"000_%1" [CR]
"ON" -----------------------Set High land ON
%1
"OFF" --------------------- Set High land OFF
"Error Code" [CR]
"000_%1"[CR]
"ON" -------------------------- Direct Power On is ON
"OFF" ------------------------ Direct Power On is OFF
"Error Code" [CR]
"000_%1" [CR]
%1
"000" – "180"(minutes)
"Error Code" [CR]
40 / 42