Cr_Backgnd Command; Cr_Disp Command; Cr_Logo Command; Cr_Ceil Command - Sanyo PLC-WL2500A Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WL2500A:
Table of Contents

Advertisement

PLC-WL2500A / WL2501A/ WL2503A Expand Serial Command Functional Specifications

9.11.4 CR_BACKGND Command

Command
Details
Response

9.11.5 CR_DISP Command

Command
"CR_DISP"[CR]
Details
Get setting status of Display
Acceptable
Response
Unacceptable

9.11.6 CR_LOGO Command

Command
"CR_LOGO"[CR]
Details
Get setting status of Logo
Acceptable
Response
Unacceptable

9.11.7 CR_CEIL Command

Command
"CR_CEIL" [CR]
Details
Get setting status of Ceiling
Acceptable
Response
Unacceptable

9.11.8 CR_REAR Command

Command
"CR_REAR" [CR]
Details
Get setting status of Rear
Acceptable
Response
Unacceptable
"CR_BACKGND" [CR]
Get setting status of Screen for no signal
Acceptable
"000_%1" [CR]
"BLUE" -------------------------------- Blue Back is selected
%1
"USER" ------------------------------- User is selected
"BLACK" ------------------------------ Black Back is selected
Unacceptable
"Error Code" [CR]
"000_%a"[CR]
"ON" -------------------------- Display is ON
%a
"OFF" ------------------------ Display is OFF
"CNTDWNOFF" ---------- Countdown OFF
"Error code"[CR]
"000_%1"[CR]
"OFF" ------------------------------ Logo function is OFF
%1
"DFLT" ----------------------------- Default Logo is selected
"USER" ---------------------------- User Logo is selected
"Error code"[CR]
"000_%1"[CR]
"ON" ------------------------------ Ceiling is ON
%1
"OFF" ----------------------------- Ceiling is OFF
"Error Code" [CR]
"000_%1"[CR]
"ON" ------------------------------ Rear is ON
%1
"OFF" ----------------------------- Rear is OFF
"Error Code" [CR]