The Default Menu is a series of informative displays with nothing to set. The OnCommand will automatically
switch to the default menu when no keys have been pressed for 2 minutes and will then scroll through each display.
The Settings Menu and the Timers Menu are the menus you will be using most often to adjust the operation of your
pool. The Configuration Menu is used when the system is installed and defines what equipment is connected to
each output and the operational logic that will control the equipment. This menu is normally "locked" and should
only be used by a pool professional. Details regarding the Configuration menu are included in both the Operation
and the Installation Manual.
The "Diagnostic Menu" is primarily intended for the service technician and contains information and details about
the system operation that are helpful in troubleshooting, if problems occur.
Settings Menu
The Settings Menu allows you to set all system operating parameters except the timeclock and countdown timers
which are part of the Timers Menu.
Spa Heater
Off
The spa heater setting will only appear if the system has been setup for "spa only" or "pool and spa"
operation and the heater control is enabled. The heater will turn on whenever the pool/spa valves are
in the "spa only" position and the filter pump is running and the spa water temperature is less than the
desired temperature setting. If you have both solar heat and a conventional heater and the solar
priority option is selected (Configuration Menu), then the conventional heater will only operate when
solar heat is NOT available.
Pool Heater
Off
The pool heater setting will only appear if the system has been setup for "pool only" or "pool and
spa" operation and the heater control is enabled. The heater will turn on whenever the pool/spa
valves are in the "pool only" or "spa spillover" position and the filter pump is running and the pool
water temperature is less than the desired temperature setting. If you have both solar heat and a
conventional heater and the solar priority option is selected (Configuration Menu), then the
conventional heater will only operate when solar heat is NOT available.
Spa Solar
102°F
The spa solar setting will only appear if the system has been setup for "spa only" or "pool and spa"
operation and the solar control is enabled. The solar system will turn on whenever the pool/spa
valves are in the "spa only" position and the filter pump is running and the spa water temperature is
less than the desired temperature setting and solar heat is available.
Pool Solar
88°F
The pool solar setting will only appear if the system has been setup for "pool only" or "pool and spa"
operation and the solar control is enabled. The solar system will turn on whenever the pool/spa
valves are in the "pool only" or "spa spillover" position and the filter pump is running and the pool
water temperature is less than the desired temperature setting and solar heat is available.
Adjust the desired spa temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item
Adjust the desired pool temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item
Adjust the desired spa temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item
Adjust the desired pool temperature (Off, 65°F, 66°F, ...103°F, 104°F, Off)
Move to previous/next menu item