JunosE 11.3.0 Release Notes

MPLS

Multicast

Netflow

Policy Management

48
Known Problems and Limitations
Work-around: Issue the clear ip mobile binding all command before you issue the no
virtual router command. The clear command clears all the MIP subscribers and
sends a RADIUS Acct-Stop message with the appropriate accounting statistics for
the subscribers.
When MPLS and IS-IS are configured on Ethernet interfaces, you cannot delete the
interface after the IP address is removed. This issue is not a problem on Ethernet
VLAN interfaces. [Defect ID 66813]
Work-around: Issue the no mpls command to disable MPLS, then delete the
interface.
If LSPs are announced into IS-IS, then the IS-IS routes cannot be used for multicast
RPF checks, because LSPs are unidirectional. [Defect ID 28526]
Work-around: Configure static RPF routes with native hops when LSPs are autoroute
announced to IGPs.
When the IPv4 explicit null label appears anywhere other than at the bottom of the
label stack, TTL expiration for this label is not handled correctly. As a result, the
traceroute command does not work correctly for LSPs that have the IPv4 explicit
null label anywhere other than at the bottom of the label stack. [Defect ID 76037]
When you issue a traceroute or trace mpls command to trace the paths of router
packets over MPLS interfaces on an ES2 10G LM or ES2 10G Uplink LM, the results
include an extra unknown host. [Defect ID 174537]
When you configure more than 10,219 outgoing interfaces (OIFs) on the same ES2
10G LM in a single multicast group, the configuration of the multicast group's OIF
membership from the SRP module to the line module exceeds the size of a single
message and is sent in fragments. Because of this fragmentation, the ES2 10G LM
generates the following error message: [Defect ID 81768]
pc: 0x9e5c88: -> fatalPanic(void) offset: 0x8
The OC3/STM1 GE/FE line module might reset after sending Ethernet traffic into a
VPLS network in a test environment when Ethernet packets are flooded to remote
VPLS bridges. [Defect ID 74540]
Flow sampling stops after a cold switchover on a router that is configured with 16
VRs and 32 interfaces per VR, when all flows are passing through the configuration
(32 flows per VR). [Defect ID 74477]
Work-around: After the cold switchover is completed, reissue the ip
flow-sampling-mode packet-interval 10 command on each VR, even though the
command is present in the configuration.
On the E320 router, redirecting a large configuration with thousands of interfaces to
a script file can take a long time, perhaps exceeding a half-hour depending on the
configuration. [Defect ID 80429]